Page 427 - Foton Workshop Manual - Auman EST-M
P. 427
Diagnosis - Diagnosis-fault diagnosis of electronic and electrical parts DI - 373
Failure phenomenon list IN
Use the list below to help you find the reasons of failures. The number represents the order of failure reason
possibility. Check each part according to the order and replace it when necessary. DI
Failure phenomenon Possible reason Failure elimination
EG
1. Generator wiring terminal Repair the wiring terminal.
Battery not charging completely 2. Generator belt Repair or replace the generator belt
TR
3. Generator Repair or replace the generator
1. Combination instrument fuse Replace the same spec fuse AX
When the ignition switch is on,
2. Line fault Repair or replace harness
the charging indicator is not
FR
3. Combination instrument Repair or replace the combination instrument.
bright (the engine does not start)
4. Generator Repair or replace the generator
ST
1. Generator belt Repair or replace the generator belt
Generator noise
2. Generator Repair or replace the generator BR
BW
EL
DI-373