Page 429 - Foton Workshop Manual - Auman EST-M
P. 429
Diagnosis - Diagnosis-fault diagnosis of electronic and electrical parts DI - 375
Failure phenomenon Phenomenon description IN
When the ignition switch is placed at "ON" position, the
Battery not charging completely DI
voltage is insufficient although the battery is charged.
Diagnosis procedure
EG
1. Check the battery wiring terminal
a. Check whether the positive and negative cables of battery are damaged, oxidized, bad contact or loose.
TR
Check if the result is ok?
Yes>go to Step 2.
AX
No > repair the relevant fault point.
2. Check the generator belt
FR
a. Check the generator belt for damage.
Check if the result is ok?
ST
Yes>go to Step 3.
No>repair or change the generator belt.
BR
3. Check the generator
a. Check the generator output voltage. BW
Is the test result ok?
Yes>charge or replace the battery.
EL
No>Repair or replace generator.
DI-375