Page 1291 - Foton Workshop Manual - Aumark (BJ1099)
P. 1291
HEATING AND AIR CONDITIONING - HEATING WATER PIPE 41-11
HEATING WATER PIPE
REPLACEMENT
NOTICE:
The replacement method is same for all heater water pipes. The section below takes the
heater water inlet pipe for instance to describe the replacement.
1. Drain the coolant (Refer to "Chapter 16 Cooling - Coolant, Replacement")
2. Remove the heating water pipe assembly
(a). Loosen the clamp screws on two sides of
the heater water inlet pipe and pull out the
rear heater water inlet pipe.
NOTICE:
While pulling out the heater water pipe, take
cautions to prevent the coolant from splashing on
your body.
3. Install the rear heater water inlet pipe
(a). Install the rear heater water inlet pipe and
tighten the clamp screws on two sides of
the heater water inlet pipe.
41
4. Fill up the coolant (Refer to "Chapter 16 Cooling - Coolant,Replacement")
Page 1291