41-12 HEATING AND AIR CONDITIONING - HEATER WATER PIPE SOLENOID VALVE
HEATER WATER PIPE SOLENOID VALVE
REPLACEMENT
1. Disconnect the negative cable of the battery (Refer to "Chapter 18 Starting &
Charging- Battery, Replacement")
2. Drain the coolant (Refer to "Chapter 16 Cooling - Coolant, Replacement")
3. Remove the heater water pipe solenoid
valve
(a). Disconnect the connector of heater water
pipe solenoid valve.
(b). Loosen the heater water pipe clamp screws
of solenoid valve and pull out the heater
water pipe.