HEATING AND AIR CONDITIONING - HEATER WATER PIPE SOLENOID VALVE 41-15
HEATER
PREPLACEMENT
1. Disconnect the negative cable of the battery (Refer to "Chapter 18 Starting &
Charging- Battery, Replacement")
2. Drain the coolant (Refer to "Chapter 16 Cooling - Coolant, Replacement")
3. Collect the refrigerant (Refer to "Chapter 41 Heating and A/C System - Refrigerant,
Replacement")
4. Remove the heater water inlet & outlet
pipes
(a). Loose the clip and disconnect the heating
water inlet and outlet pipes.
41
5. Remove the instrument panel (Refer to "Chapter 52 Instrument Panel & Auxiliary
Instrument Panel - Instrument Panel, Replacement")
6. Remove the steering column beam welded assembly (Refer to "Chapter 37 Steering
Mechanism - Steering Column Assembly, Replacement")
7. Remove the hvac assembly
(a). Unscrew the fastening bolts of the A/C
pipe clamp and disconnect the pipe.