Page 1803 - Foton Workshop Manual - Aumark (BJ1099)
P. 1803
CIRCUIT - BASIC MAINTENANCE 61-13
(d). With a small screwdriver into the socket to
open the lock ring, pull out the terminal.
△ PROMPT:
To write down the corresponding connector hole 61
of each terminal when you pull out the terminal,
thus can improve the installation speed, avoid re-
viewing the terminal.
(e). Replace with a new connector, adjust the
wire terminal to a proper angle inserting
into the connector.
NOTICE:
Straighten out the terminal lead wire, and the
cross lead wire is not permitted.
fuwx61028
(f). Put the protective sleeve into the connector
and press tightly.
fuwx61029
(g). Docking connectors at both ends, if heard
"pa" sound, indicating that the docking is
completed.
NOTICE:
After docking is completed, gently pull out the
two ends, if you can pull out, the connector is
damaged, it must be replaced.
fuwx61030
Page 1803