61-16                            CIRCUIT - BASIC MAINTENANCE


                                                              • Use pliers to press the wire core and the
                                                                copper connecting sleeve pile as a whole.














                                                              • Insulation wrap treatment.
















                                                      (c).    Connector method.
                                                              •Strip some insulation layer on the two
                                                                   ends of the broken end.












                                                              •Respectively put the two cores on the
                                                               connector's connecting piece.














                                                              •Connect the connector.