62-198                      DIAGNOSIS-HEATER & AIR CONDITIONING

           BASIC INSPECTION


              Procedures                 Inspection contents                           Action

                             Check battery voltage                Yes                Go to step 2
                   1         • The battery voltage is24V.
                             Is the result normal?                 No         Charge or replace the battery

                             Check if there is any refrigerant    Yes                Go to step 3
                             •  Unscrew maintenance valve
                                protection cover of air conditioning
                   2
                                refrigeration system, press and    No             Add the refrigerant
                                hold valve element.
                             Is the result normal?
                             Check A/C switch                     Yes                Go to step 4
                             • Start the air conditioning
                   3         • Visually check if the air
                                conditioning work lamp lights up.  No          Go to Fault Symptom Table
                             Is the result normal?

                             Check magnet clutch                  Yes                Go to step 5
                             •  Check if the electromagnetic
                   4
                                clutch works normally              No          Go to Fault Symptom Table
                             Is the result normal?

                             Check driving belt                   Yes                Go to step 6
                   5         • Check if the driving belt slips.
                             Is the result normal?                 No          Go to Fault Symptom Table
                             Check compressor                     Yes                Go to step 7
                             •  Check if the compressor has
                   6            any abnormal sound when it is
                                working.                           No          Go to Fault Symptom Table
                             Is the result normal?

                             Check condenser                      Yes                Go to step 8
                             •  Check if there is any debris
                                between condenser and radiator.
                   7         •  Check if the condenser fan works
                                normally.                          No      Clear debris replace condenser fan
                             Check if the condenser works
                                normally?

                             Check refrigerant dose               Yes                Go to step 9
                             •  Observe the refrigerant dose in
                   8
                                the system through peep hole.      No          Go to Fault Symptom Table
                             Is the result normal?






                                                                                                     Page 2250
   2245   2246   2247   2248   2249   2250   2251   2252   2253   2254   2255