Page 2279 - Foton Workshop Manual - Aumark (BJ1099)
P. 2279

DIAGNOSIS-HEATER & AIR CONDITIONING                          62-227

                 3.     Check the harness and the connector (start-up tripping relay -grounding)


                 (a).         Disconnect the battery negative cable.
                 (b).         Unplug the start-up tripping relay R04.
                 (c).         Connect battery negative cable.
                 (d).         Start engine.                                                                         62
                 (e).         Turn on A/C Switch.


                                                            (f).   Measure the voltage according to the
                                                                   values in the table below.
                                                                        Standard Voltage:

                                                                         Connect by          Standard value
                                                                         multimeter
                                                                      R14(2)—Grounding
                                                                                                Battery volt
                                                                      R14(3)—Grounding


                 Is the result normal?
                 Yes>To step 4.
                 No >Repair or replace the harness.


                 4.     Check air condition  compressor relay


                 (a).   Disconnect the battery negative cable.
                 (b).   Unplug air conditioning compressor relay R14.


                                                            (c).   Check air condition compressor relay R14.
                                                                   Standard resistance:


                                                                      Conditions      Multimeter  Specified
                                                                                       connection       value

                                                                        Normalcy           1-2         Breakover

                                                                     T o  impose
                                                                     voltage between       3-5          < 2Ω
                                                                        pin1and2


                 Is the result normal?
                 Yes>To step5.
                 No >Replace the air conditioning compressor relay to validate again whether this fault
                         exists or not.










                                                                                                     Page 2279
   2274   2275   2276   2277   2278   2279   2280   2281   2282   2283   2284