Page 2275 - Foton Workshop Manual - Aumark (BJ1099)
P. 2275

DIAGNOSIS-HEATER & AIR CONDITIONING                          62-223

                                                            (c).   Check rear blower switch connector D53
                                                                   by using the omh band of the multimeter.
                                                                   Standard resistance: (check whether there
                                                                   is an open circuit)
                                                                     Connect the pin by      Standard value
                                                                         multimeter                                 62

                                                                      D53(1)—Grounding
                                                                                                  < 2 Ω
                                                                      D53(3)—Grounding
                 Is the result normal?
                 Yes>Go to the next step.
                 No >Repair or replace the harness.


                 9.     Check the harness and the connector (rear blower switch-air-condition controller )


                 (a).   Disconnect the battery negative cable.
                 (b).   Disconnect rear blower switch connector D53.


                                                            (c).   Disconnect air conditioning controller
                                                                   connector C42.





















                                                 fuwx62 606

                                                            (d).   Measure the resistance according to values
                                                                   in the table below.
                                                                      Standard resistance: (check whether there
                                                                   is an open circuit)


                                                                     Connect the pin by      Standard value
                                                                         multimeter

                                                                       D53(2)—C42(B9)             < 2 Ω