Page 2271 - Foton Workshop Manual - Aumark (BJ1099)
P. 2271
DIAGNOSIS-HEATER & AIR CONDITIONING 62-219
Diagnosis Procedure
1. Check the fuse
(a). Disconnect the battery negative cable.
62
(b). Check the fuse in fuse box within engine
housing:
Disconnect Normal
• F30(30A)
(c). Check the fuse in fuse box within house:
• F17(5A)
• F33(5A)
fuwx62605
Is the result normal?
Yes>To step 2.
No >Replace the fuse.
2. Check the start to cut off the relay
(a). Disconnect the battery negative cable.
(b). Unplug the start-up tripping relay R04.
(c). Check the start-up tripping relay R04.
Standard resistance:
Conditions Connect by Specified
multimeter value
Ordinary state 1-2 Existed
Apply the
battery voltage
between the No. 3-4 < 2Ω
1 and No. 2 pin
Is the result normal?
Yes>To step 3.
No >change start to cut off the relay, to validate whether the fault exists or not.
3. Check rear blower relay
(a). Disconnect the battery negative cable.
(b). Remove rear blower relay R05.
Page 2271