Page 2268 - Foton Workshop Manual - Aumark (BJ1099)
P. 2268
62-216 DIAGNOSIS-HEATER & AIR CONDITIONING
7. (Check the harness and the connector (the front blower speed regulation resistance
-grounding)
(a). Disconnect the battery negative cable.
(b). Disconnected front blower speed regulation resistance connector C39.
(c). Check blower speed regulation resistance
connector C39 by using multimeter
resistance.
Standard resistance: (check whether there
is an open circuit)
Connect the pin by Standard value
multimeter
C39(1)—Grounding < 2 Ω
Is the result normal?
Yes>To step 8.
No >Repair or replace the harness.
8. Check the harness and the connector (the front blower speed regulation resistance
-air conditioning controller)
(a). Disconnect the battery negative cable.
(b). Disconnected front blower speed regulation resistance connector C39.
(c). Disconnect air conditioning controller
connector C42.
fuwx62 606
Page 2268