Page 2268 - Foton Workshop Manual - Aumark (BJ1099)
P. 2268

62-216                      DIAGNOSIS-HEATER & AIR CONDITIONING


           7.     (Check the harness and the connector (the front blower speed regulation resistance
                  -grounding)


           (a).   Disconnect the battery negative cable.
           (b).   Disconnected front blower speed regulation resistance connector C39.

                                                      (c).    Check blower speed regulation resistance
                                                              connector C39 by using multimeter
                                                              resistance.
                                                              Standard resistance: (check whether there
                                                              is an open circuit)

                                                               Connect the pin by       Standard value
                                                                   multimeter

                                                                C39(1)—Grounding             < 2 Ω
           Is the result normal?
           Yes>To step 8.
           No >Repair or replace the harness.


           8.     Check the harness and the connector (the front blower speed regulation resistance
                  -air conditioning controller)


           (a).   Disconnect the battery negative cable.
           (b).   Disconnected front blower speed regulation resistance connector C39.


                                                      (c).    Disconnect air conditioning controller
                                                              connector C42.





















                                           fuwx62  606
















                                                                                                     Page 2268
   2263   2264   2265   2266   2267   2268   2269   2270   2271   2272   2273