62-220                      DIAGNOSIS-HEATER & AIR CONDITIONING


                                                      (c).    Check rear blower relay R05.
                                                                 Standard resistance:

                                                                                Connect by  Specified
                                                                Conditions
                                                                                  multimeter       value
                                                                Ordinary state      85–86         Existed

                                                                  Apply the
                                                                battery voltage
                                                                 between the        30–87          < 2Ω
                                                               No.85 and No.86
                                                                     pin
           Is the result normal?
           Yes>To step 4.
           No >Replace the rear blower relay to validate again whether this fault exists or not.


           4.     Check the wiring harness and  connectors (rear blower relay - rear blower motor)


           (a).   Disconnect the battery negative cable.


                                                      (b).    Disconnecting blower connectors D59.
                                                       (c).   Unplug the rear blower relay R05.





















                                           fuwx62  621


                                                      (d).    Measure the resistance according to values
                                                              in the table below.
                                                              Standard resistance: (check whether there
                                                              is an open circuit)
                                                                   Connect by           Standard value
                                                                   multimeter

                                                                 R05(87)—D59(1)              < 2 Ω