62-222                      DIAGNOSIS-HEATER & AIR CONDITIONING


                                                      (d).    Measure the resistance according to values
                                                              in the table below.
                                                                  Standard resistance: (check whether there
                                                              is an open circuit)

                                                               Connect the pin by       Standard value
                                                                   multimeter
                                                                  D53(4)—D57(4)

                                                                  D53(5)—D57(3)              < 2 Ω

                                                                  D53(6)—D57(1)
           Is the result normal?
           Yes>To step 7.
           No >Repair or replace the harness.


           7.     Check rear blower motor


           (a).   Ignition switch:"OFF".
           (b).   Disconnect rear blower motor connector D59.


                                                      (c).    Check the function of rear blower motor
                                                              D59.

                                                                                Connect the  Specified
                                                                Conditions
                                                                                     pins          value

                                                                  Apply the       Battery (+)-1
                                                                battery voltage                    Front
                                                                                                   blower
                                                               between the No.    Battery(-)-2   motor run
                                                               1 and No. 2 pin
           Is the result normal?
           Yes>To step 8.
           No >Replace the rear blower motor.


           8.     Check the harness and the connector (rear blower switch-grounding)


           (a).   Disconnect the battery negative cable.
           (b).   Disconnect rear blower switch connector D53.