Page 2267 - Foton Workshop Manual - Aumark (BJ1099)
P. 2267

DIAGNOSIS-HEATER & AIR CONDITIONING                          62-215

                                                            (b).   Disconnected front blower speed regulation
                                                                   resistance connector C39.





                                                                                                                    62














                                                 fuwx62 615

                                                            (c).   Disconnected front blower connector C40.























                                                 fuwx62 613

                                                            (d).   Measure the resistance with the multimeter
                                                                   on the resistance range.
                                                                       Standard resistance: (check whether there
                                                                   is an open circuit)

                                                                     Connect the pin by      Standard value
                                                                         multimeter
                                                                        C39(4)—C40(2)             < 2 Ω


                 Is the result normal?
                 Yes>To step6.
                 No >Repair or replace the harness.












                                                                                                     Page 2267