62-390                           DIAGNOSIS-LIGHTING SYSTEM


           Is the result normal?
           Yes>To step 3.
           No >Replace the bulb.


           3.     Check the harness disconnection


           (a).   Disconnect left daytime running light connector A44, right daytime running light
                  connector A43 and body controller C56.


                                                      (b).    Use a multimeter to measure the voltage
              ON                                              between No. 5 terminal of body controller
                            T.S
                                       v                      C56 and the ground.
                                                              Standard resistance: (check whether there
                                                              is an open circuit)
                                C56
               1 2  3        4 5                               Connect the pin by
               6 7 8     10  1112                                                       Standard value
                                                                   multimeter
                                           fuwx62 873
                                                                C56(5) - Grounding         Battery volt


                                                      (c).    Use a multimeter to measure the resistance
                                                              between No. 1 terminal of left daytime
                                                              running light A44 and No. 11 terminal of
                                                              body controller C56.
                                                              Standard resistance: (check whether there
                                                              is an open circuit)


                                                               Connect the pin by       Standard value
                                                                   multimeter

                                                                  A44(1) - C56(11)           ≤ 2 Ω



                                                      (d).    Use a multimeter to measure the resistance
                                                              between right daytime running light A43
                                                              and No. 11 terminal of body controller C56.
                                                              Standard resistance: (check whether there
                                                              is an open circuit)

                                                               Connect the pin by       Standard value
                                                                   multimeter

                                                                  A43(1) - C56(11)           ≤ 2 Ω