Page 2444 - Foton Workshop Manual - Aumark (BJ1099)
P. 2444
62-392 DIAGNOSIS-LIGHTING SYSTEM
(d). Use a multimeter to measure the resistance
between No. 1 terminal of the left daytime
running light connector A43 and the
ground.
Standard resistance: (check whether there
is a short circuit)
Connect the pin by Standard value
multimeter
A43(1) - Grounding > 1 MΩ
Is the inspection result normal?
Yes>Replace BCM body controller.
No >Repair harness short circuit to ground between connector C56 to daytime running
light fuse, C56 to A44, C56 to A43.
Page 2444