62-392                           DIAGNOSIS-LIGHTING SYSTEM


                                                      (d).    Use a multimeter to measure the resistance
                                                              between No. 1 terminal of the left daytime
                                                              running light connector A43 and the
                                                              ground.
                                                              Standard resistance: (check whether there
                                                              is a short circuit)

                                                               Connect the pin by       Standard value
                                                                   multimeter
                                                                A43(1) - Grounding          > 1 MΩ

           Is the inspection result normal?
           Yes>Replace BCM body controller.
           No >Repair harness short circuit to ground between connector C56 to daytime running
                   light fuse, C56 to A44, C56 to A43.