Page 2468 - Foton Workshop Manual - Aumark (BJ1099)
P. 2468
62-416 DIAGNOSIS-COMBINATION METER
TABLE OF MALFUNCTION SYMPTOMS
Using the table below will help you to find the cause of the faults. Serial number shows the
sorting of fault causes possibility. Check each part according to this sequence and replace
it if necessary.
Whole System
Malfunction Possible Cause Reference
Symptoms
1.Power supply circuit ( such
as fuse blown)
The whole combination Chapter 62 diagnosis-combination meter, the
meter does not work 2.Combination meter fault whole combination meter does not work
3.Harness or connector open
circuit
Instrument Measurement Table
Malfunction Possible Cause Reference
Symptoms
1.ABS system fault
2.CAN bus communication
line fault Chapter 62 diagnosis-combination meter,
Speedometer Fault
3.Combination meter fault speedometer fault
4.Harness or connector
damage
1.Fuel sensor fault
2.Combination meter
Fuel gauge fault assembly fault Chapter 62 diagnosis-combination meter, fuel
gauge fault
3.Harness or connector
damage
Warning Lamp
Malfunction Possible Cause Reference
Symptoms
1.Brake fault warning lamp
switch
2.Brake fault warning lamp
Brake fault warning circuit Chapter 62 diagnosis-combination meter, brake
lamp does not turn on/ fault warning lamp does not turn on/is always on
is always on 3.Combination meter
assembly fault
4.Harness or connector open
circuit or short circuit
Page 2468