Page 2473 - Foton Workshop Manual - Aumark (BJ1099)
P. 2473

DIAGNOSIS-COMBINATION METER                               62-421

                                                            (c).   Use multimeter to measure the resistance
                                                                   between No.1 pin of combination meter
                                                                   C23 connector and the grounding.
                                                                        Standard resistance: (check whether there
                                                                   is a short circuit)
                                                                                                                    62
                                                                     Connect the pin by      Standard value
                                                                         multimeter
                                                                      C23 (1) - Grounding        > 1 MΩ



                                                            (d).   Use multimeter to measure the resistance
                                                                   between No.3 pin of combination meter
                                                                   C23 connector and the grounding.
                                                                        Standard resistance: (check whether there
                                                                   is a short circuit)

                                                                     Connect the pin by      Standard value
                                                                         multimeter

                                                                      C23(3) - Grounding         > 1 MΩ


                 Is the result normal?
                 Yes>Replace combination meter assembly.
                 No >Repair the short circuit to ground from fuse F26(7.5 A) to No.1 pin of combination
                         meter C23 connector;
                       Repair the short circuit to ground from fuse F7(7.5 A) to No.3 pin of combination
                         meter C23 connector.