Page 2472 - Foton Workshop Manual - Aumark (BJ1099)
P. 2472

62-420                          DIAGNOSIS-COMBINATION METER


                                                      (c).    Use multimeter to measure the voltages
                                                              between No.1 & No.3 pin of combination
              OFF
                                       v                      meter C23 connector and the ground
                                                              connection.
                           C23
                                                                 Standard voltage:
            4  13 12  11 10  9  8  7  6  5  4  3  2  1
            0  29 28 27  26  25  24  23  22  21  20  19  18 17  Connect the pin by      Standard value
                                                                   multimeter
                                           fuwx62905
                                                                C23 (1) - Grounding
                                                                                           Battery volt
                                                                C23 (3) - Grounding
           Is the result normal?
           Yes>To step 3.
           No >If there is no battery voltage in No.1 pin of combination meter C23 connector, repair
                   the open circuit from fuse F7(7.5 A) to No.1 pin of combination meter C23 connector.


           3.     Check harness and connector (combination meter-grounding)


           (a).   Ignition switch:"LOCK".


                                                      (b).    Use multimeter to measure the voltages
                                                              between No.2 pin of combination meter
              OFF
                                      Ω                       C23 connector and the grounding.
                                                                 Standard resistance:
                           C23
                                                               Connect the pin by       Standard value
                                                                   multimeter
            4  13 12  11 10  9  8  7  6  5  4  3  2  1
            0  29 28 27  26  25  24  23  22  21  20  19  18 17
                                                                C23 (2) - Grounding          ≤ 2 Ω
                                           fuwx62906


           Is the result normal?
           Yes>Replace combination meter assembly.
           No >Repair the circuit between No.2 pin of combination meter C23 connector and the
                  grounding.


           4.     Check combination meter circuit


           (a).   Ignition switch:"LOCK".
           (b).   Disconnect combination meter connector C23.