Page 2469 - Foton Workshop Manual - Aumark (BJ1099)
P. 2469
DIAGNOSIS-COMBINATION METER 62-417
1.Water temperature sensor
fault
2.Brake fluid level warning
Coolant over- switch fault
temperature indicator 3.CAN communication bus Chapter 62 diagnosis-combination meter, 62
coolant over-temperature indicator lamp does
lamp does not turn fault not turn on/is always on
on/is always on 4.Combination meter
assembly fault
5.Harness or connector open
circuit or short circuit
Indicator lamp
Malfunction Possible Cause Reference
Symptoms
1.Oil pressure switch fault
2.Oil pressure indicator lamp
Oil pressure indicator circuit fault
lamp does not turn on/ 3.Combination meter Chapter 62-combination meter, oil pressure
indicator lamp does not turn on/is always on
is always on assembly
4.Harness or connector open
circuit or short circuit
1.Fuse damaged
Vacuum warning 2.Vacuum degree alarm fault
indicator lamp does 3.Combination meter Chapter 62-combination meter, vacuum warning
not turn on/is always assembly fault indicator lamp does not turn on/is always on
on
4.Harness or connector open
circuit or short circuit
LCD
Malfunction Possible Cause Reference
Symptoms
The speedometer
cannot be displayed, 1.LCD damage Chapter 62-Combination Meter, Replace
or the display is blur
Page 2469