DIAGNOSIS-COMBINATION METER                               62-417

                                         1.Water temperature sensor
                                           fault

                                         2.Brake fluid level warning
                      Coolant over-        switch fault
                   temperature indicator   3.CAN communication bus     Chapter 62 diagnosis-combination meter,      62
                                                                     coolant over-temperature indicator lamp does
                    lamp does not turn       fault                   not turn on/is always on
                     on/is always on     4.Combination  meter

                                           assembly fault
                                         5.Harness or connector open
                                           circuit or short circuit

                 Indicator lamp


                      Malfunction            Possible Cause                          Reference
                       Symptoms

                                         1.Oil pressure switch fault

                                         2.Oil pressure indicator lamp
                   Oil pressure indicator   circuit fault
                  lamp does not turn on/  3.Combination  meter       Chapter 62-combination meter, oil pressure
                                                                     indicator lamp does not turn on/is always on
                       is always on        assembly

                                         4.Harness or connector open
                                           circuit or short circuit
                                         1.Fuse damaged

                     Vacuum warning      2.Vacuum degree alarm fault
                    indicator lamp does   3.Combination  meter       Chapter 62-combination meter, vacuum warning
                   not turn on/is always   assembly fault            indicator lamp does not turn on/is always on
                           on
                                         4.Harness or connector open
                                           circuit or short circuit
                 LCD


                      Malfunction            Possible Cause                          Reference
                       Symptoms
                    The speedometer
                   cannot be displayed,   1.LCD damage               Chapter 62-Combination Meter, Replace
                   or the display is blur