DIAGNOSIS-COMBINATION METER                               62-425

                 5.     Check the short circuit of oil pressure indicator lamp signal circuit


                                                            (a).   Measure  the  resistance  between  the
                                                                   grounding and the No.1 pin of oil pressure
                                                                   switch E05 connector by multimeter.
                                                                       Standard voltage:                            62
                                                                     Connect the pin by      Standard value
                                                                         multimeter

                                                                      E05 (1) - Grounding        > 1 MΩ


                 Is the result normal?
                 Yes>To step6.
                 No >Check the short circuit to ground between No.1 pin of oil pressure switch E05 and
                          No.37 pin of engine ECU connector E01.


                 6.     Check CAN communication line


                                                            (a).   Disconnect engine ECU connector A11,
                                                                   turn ignition switch "ON",check the voltage
                                                                   between the grounding and No.14 & No.15
                                                                   pin of A11.
                                                                       Standard voltage:

                                                                     Connect the pin by       Standard value
                                                                          multimeter

                                                                      A11 (14) - Grounding        2.5V~5V
                                                                      A11 (15) - Grounding        0V~2.5V


                 (b).   Disconnect the battery negative cable, check the resistance between No.14 and
                        No.15 pin of A11.
                        Standard resistance: 60Ω
                  (c).   Disconnect combination meter connector, check the continuity between No.14 pin
                        of engine ECU connector A11 and No.16 pin of combination meter connector C23,
                        and the continuity between No.15 pin of A11 and No.15 pin of combination meter
                        connector C23.

                 Is the result normal?
                 Yes>To step7.
                 No >Check whether CAN communication terminal resistance A42 is intact, and repair the
                         corresponding CAN communication harness open circuit fault.