Page 2484 - Foton Workshop Manual - Aumark (BJ1099)
P. 2484

62-432                          DIAGNOSIS-COMBINATION METER


           Diagnosis Procedure


           1.     Check vacuum degree alarm


           (a).   Idle run the engine, check whether the vacuum pump works well, check whether the
                  pipeline connected to vacuum pump is well connected, check whether the vacuum
                  tube of brake master cylinder exist air leakage phenomenon.
           (b).   Disconnect the vacuum alarm connector A17.
           (c).   Ignition switch:"ON",check whether the vacuum warning indicator lamp turns off.

                                                      (d).    Measure the continuity between No.1 and
                                                              No.2 pin of vacuum alarm by multimeter.













                                                      (e).    Measure  the  continuity  between  the
                                                              grounding and No.2 pin of vacuum alarm
                                                              connector by multimeter.











           Is the result normal?
           Yes>To step2.
           No >Repair vacuum pump and its pipeline, or replace vacuum alarm, or check the
                   grounding line of vacuum alarm.


           2.     Check vacuum warning indicator lamp signal circuit


           (a).   Ignition switch:"LOCK".



















                                                                                                     Page 2484
   2479   2480   2481   2482   2483   2484   2485   2486   2487   2488   2489