Page 2501 - Foton Workshop Manual - Sauvana
P. 2501
DIAGNOSIS-COMBINATION METER 62-449
(b). Use multimeter to measure the resistance
between No.8 pin of combination meter
C23 connector and No.1 pin of brake fluid
level warning switch connector A18.
Standard resistance: (check whether there
is an open circuit) 62
Connect the pin by Standard value
multimeter
C23(8) - A18(1) ≤ 2 Ω
Is the result normal?
Yes>Replace combination meter assembly.
No >Repair the open circuit between No.8 pin of combination meter C23 connector and
No.1 pin of brake fluid level warning switch A18 connector.