Page 2020 - Foton Workshop Manual - Tunland (AT)
P. 2020

61-24                   HEATER AND AIR CONDITIONING - REFRIGERANT

           REFRIGERANT

           CHECK

           Leakage test can only be performed when the pressure inside the A/C system is no less than
      61
           0.196MPa. However, don't inject compressed air into the system, or the moisture, dust or
           other impurities in the air may deteriorate the drying agent or contaminate the system. Check
           refrigerant leakage in any of the following methods:
           1 .    Measure the system pressure with manifold pressure gauge
           (a)    It detects the defect with a manifold pressure gauge. Read the manifold pressure
                  gauge under the following conditions.
                  Test conditions:

                  Inlet temperature: 30 ~ 35℃
                  Engine RPM: 1500
                  Blower RPM: Max.

                  Temperature switch: Cool
                  A/C switch: On

                  All doors open
                NOTICE

           The tables below show the data when the cooling system is switched on, without
           vacuuming before refrigerant replacement.


                                                      •      Pressure gauge reading in normal
                                                             operation:
                                                             Low pressure: 0.2–0.4MPa

                                                             High pressure: 1.2–2.0MPa













           •      Steam in the system (condition: no cooling intermittently)
























                                                                                                        Page 2020
   2015   2016   2017   2018   2019   2020   2021   2022   2023   2024   2025