Page 349 - Foton Workshop Manual - Tunland (AT)
P. 349
DIAGNOSTICS - ENGINE CONTROL SYSTEM 04-203
Multimeter connection pin Standard value
A19(1)- A024(46) <2 Ω
A19(2)- A024(21) <2 Ω
(l) Use a multimeter to measure the resistance between the pin 1, 2 of intake heater relay
04
A19 and the ground respectively.
Standard resistance
Multimeter connection pin Standard value
A19(1)- ground > 10 MΩ
A19(2)- ground > 10 MΩ
Is the inspection result normal?
YES>To step 5.
No > Maintain or replace the harness.
5 . Replace the intake heater
(a) Replace the intake heater.
(b) Use a diagnostic apparatus to perform DTC verification procedures.
(c) Implement the steps to read sensor data stream.
(d) Check whether DTC exists.
Is the inspection result normal?
YES>Replace the intake heater.
NO >To step 6.
6 . Replace ECM
(a) Replace ECM.
(b) Use a diagnostic apparatus to perform DTC verification procedures.
(c) Implement the steps to read sensor data stream.
(d) Verify that no DTC exists and the data are normal.
Page 349