     DIAGNOSTICS - ENGINE CONTROL SYSTEM                          04-203
                          Multimeter connection pin                              Standard value
                            A19(1)- A024(46)                                          <2 Ω
                            A19(2)- A024(21)                                          <2 Ω
                 (l)    Use a multimeter to measure the resistance between the pin 1, 2 of intake heater relay
                                                                                                                     04
                        A19 and the ground respectively.
                        Standard resistance
                          Multimeter connection pin                              Standard value
                               A19(1)- ground                                       > 10 MΩ
                               A19(2)- ground                                       > 10 MΩ
                 Is the inspection result normal?
                 YES>To step 5.
                 No > Maintain or replace the harness.
                 5 .    Replace the intake heater
                 (a)    Replace the intake heater.
                 (b)    Use a diagnostic apparatus to perform DTC verification procedures.
                 (c)    Implement the steps to read sensor data stream.
                 (d)    Check whether DTC exists.
                 Is the inspection result normal?
                 YES>Replace the intake heater.
                 NO >To step 6.
                 6 .    Replace ECM
                 (a)    Replace ECM.
                 (b)    Use a diagnostic apparatus to perform DTC verification procedures.
                 (c)    Implement the steps to read sensor data stream.
                 (d)    Verify that no DTC exists and the data are normal.