04-198                     DIAGNOSTICS - ENGINE CONTROL SYSTEM


           (a)    Ignition switch: OFF.
           (b)    Disconnect the battery negative cable.
           (c)    Disconnect intake mass flow sensor connector E07.
           (d)    Connect the battery negative cable.
           (e)    Ignition switch: ON.
      04
                                                      (f)    Use a multimeter to measure the voltage
                                                             between the pin 2 of intake mass flow sensor
                                                             connector E07 and ground.
                                                             Standard voltage

                                                       Multimeter connection
                                                                                      Standard value
                                                                 pin
                                                          E07(2)- ground              Battery voltage












           Is the inspection result normal?
           YES>To step 4.
           No > Maintain or replace the harness.


           4 .    Check intake mass flow sensor harness
           (a)    Ignition switch: OFF.
           (b)    Disconnect the battery negative cable.
           (c)    Disconnect intake mass flow sensor connector E07.
           (d)    Disconnect connector E01 of ECM.

                                                      (e)    Use a multimeter to measure the resistance
                                                             between the pin 1, 3, 4 of intake mass flow
                                                             sensor connector E07 and the pin 80, 40, 22
                                                             of ECM connector E01 respectively.

                                                             Standard resistance:

                                                       Multimeter connection
                                                                                      Standard value
                                                                 pin
                                                       E07(1)- E01(80)                    <10 Ω

                                                       E07(3)- E01(40)                    <10 Ω

                                                       E07(4)- E01(22)                    <10 Ω