Page 442 - Foton Workshop Manual - Tunland (AT)
P. 442
04-296 DIAGNOSTICS - ENGINE CONTROL SYSTEM
Diagnosis Procedure
NOTICE
• To implement the following steps, ensure that ECM is grounded properly.
• Before conducting electric diagnosis, do refer to the reference circuit diagram
and the element information.
04
• Before conducting measurement, check the pins of connectors for rupture,
looseness and rust, and ensure that the pins are contacted properly.
• If the connection is good, check the sensor signal voltage when moving the
connector and harness. If a fault occurs, the voltage display on the diagnostic
instrument will change.
1 . DTC inspection
(a) Ignition switch: OFF.
(b) Connect the diagnostic apparatus.
(c) Use the diagnostic apparatus, read the fault code.
(d) Confirm whether there is fault code related to VGT actuator ?
Is the inspection result normal?
YES>To step 2.
NO>Intermittent trouble exists.
2 . Check VGT actuator circuit
(a) Ignition switch: OFF.
(b) Disconnect the battery negative cable.
(c) Disconnect turbocharger connector E05.
(d) Connect the battery negative cable.
(e) Ignition switch: ON.
(f) Use a multimeter to measure the voltage
between the pin 4 of the turbocharger
connector E05 and the ground.
Standard voltage
Multimeter connection
Standard value
pin
E05(4)-ground 4.75~5.25 V
Is the inspection result normal?
YES>To step 3.
No > Maintain or replace the harness.