Page 443 - Foton Workshop Manual - Tunland (AT)
P. 443
DIAGNOSTICS - ENGINE CONTROL SYSTEM 04-297
3 . Check VGT actuator harness
(a) Ignition switch: OFF.
(b) Disconnect the battery negative cable.
(c) Disconnect turbocharger connector E05.
(d) Disconnect connector E01 of ECM.
04
(e) Use a multimeter to measure the resistance
between the pin 1, 3, 5 of turbocharger
connector E05 and the pin 55, 16, 15 of ECM
connector E01 respectively.
Standard resistance
Multimeter connection
Standard value
pin
E05(1)- E01(55) <10 Ω
E05(3)- E01(16) <10 Ω
E05(5)- E01(15) <10 Ω
(f) Use a multimeter to measure the resistance
between the pin 1, 3, 5 of turbocharger
connector E05 and the ground respectively.
Standard resistance
Multimeter connection
Standard value
pin
E05(1)- ground > 10 MΩ
E05(3)- ground > 10 MΩ
E05(5)- ground > 10 MΩ
Is the inspection result normal?
YES>To step 4.
No > Maintain or replace the harness.
4 . Replace turbocharger
(a) Replace turbocharger.
(b) Use a diagnostic apparatus to perform DTC verification procedures.
(c) Implement the steps to read sensor data stream.
(d) Check whether DTC exists.
Is the inspection result normal?
YES>Replace turbocharger.
Page 443