Page 803 - Foton Workshop Manual - Tunland (AT)
P. 803

DIAGNOSTICS - POWER WINDOW                              04-657

                                                           (d)    Measure the electrical resistance based on
                                                                  the value in the following form.
                                                                  Standard resistance (check whether there
                                                                  is an open circuit)

                                                            Multimeter connection          Standard value
                                                                                                                     04
                                            J004                                                < 2 Ω
                            8  7  6  5  4  3  2  1            J004(11)- ground
                           16  15  14 13  12  11  10  9







                                                 ftwxd041498


                 Check whether the result is normal?
                 Yes> Yes> go to step 5.
                 No > Maintenance or replace harness.


                 5 .    Check harness and connector (power window switch, right rear door-BCM control
                        unit)
                 (a)    Ignition Switch: OFF.

                                                           (b)    Press down power window switch H001, right
                                                                  rear door.






















                                                           (c)    Disconnect connector C035, BCM control unit.