04-658                          DIAGNOSTICS - POWER WINDOW

                                                      (d)    Measure the electrical resistance based on
                                                             the value in the following form.
                                                             Standard resistance (check whether there
                                                             is an open circuit)

                                                       Multimeter connection          Standard value
      04
                                                        H001(3)-C035(D8)                  < 2 Ω













           Check whether the result is normal?
           Yes> go to step 6.
           No > Maintenance or replace harness.


           6 .    Check harness and connector (power window switch, right rear door-ground)
           (a)    Ignition Switch: OFF.

                                                      (b)    Press down power window switch H001, right
                                                             rear door.