04-660                          DIAGNOSTICS - POWER WINDOW

                                                      (d)    Measure the electrical resistance based on
                                                             the value in the following form.
                                                             Standard resistance (check whether there
                                                             is an open circuit)

                                                       Multimeter connection          Standard value
      04
                                                       H004(T1)-C033(B9)
                                                                                          < 2 Ω
                                                       H004(T2)-C033(B10)










           Check whether the result is normal?
           Yes> Replace power window motor, right rear door.
           No > Maintenance or replace harness.




























































                                                                                                         Page 806