Page 2027 - Workshop Manual - Tunland (2017)
P. 2027

HEATER AND AIR CONDITIONING - REFRIGERANT                         61-21

                                                           (b)    Turn on the high pressure and low pressure
                                                                  valves of the A/C refrigerate collecting/filling
                                                                  system.
                                                           (c)    Select the "Vacuum" operation of the A/C
                                                                  refrigerate collecting/filling system and set the    61
                                                                  timer to 15 minutes.
                                                           (d)    Start the vacuuming process of the A/C
                                                                  refrigerate collecting/filling system.When the
                                                                  set timer is reached, the system will stop
                                                                  working.
                                                 ftwx611013
                                                           (e)    Turn off the high pressure and low pressure
                                                                  valves at the connectors of the A/C refrigerate
                                                                  collecting/filling system and record the reading
                                                                  of the pressure gauge.
                                                           (f)    Maintain the pressure for 15 minutes. If the
                                                                  reading remains unchanged, it means there
                                                                  is no leakage in the A/C pipe. Top up the
                                                                  refrigerant, lubricant and coolant. If the
                                                                  reading grows, check for leakage in the A/C
                                                                  system.
                                                           (g)    Disconnect the connectors of the A/C
                                                                  refrigerate collecting/filling system to the high
                                                                  and low ends of the A/C system respectively.

                                                           3 .    Fill up the Refrigerant

                                                           (a)    Connect the connectors of the A/C refrigerate
                                                                  collecting/filling system to the high and low
                                                                  ends of the A/C system respectively.
                                                           (b)    Vacuum the A/C system.
                                                           (c)    Top up the coolant.
                                                           (d)    Select the "Refrigerant Filling" option of the
                                                                  A/C refrigerate collecting/filling system and
                                                                  set the filling volume.
                                                 ftwx611012       A/C refrigerant filling volume: 700±50g


                                                           (e)    Turn on the low pressure valve at the
                                                                  connector of the A/C refrigerate
                                                                  collecting/filling system, start the system and
                                                                  top up the refrigerant.
                                                           (f)    Watch the display of the A/C refrigerate
                                                                  collecting/filling system. When the filling
                                                                  volume reaches the set value, the display will
                                                                  inform you that the filling is complete.



                                                 ftwx611013