Page 2026 - Workshop Manual - Tunland (2017)
P. 2026

61-20                   HEATER AND AIR CONDITIONING - REFRIGERANT

           REPLACEMENT

                CAUTION

           Use the right refrigerant service systems designed for this model.
      61
           Since leakage is common in the A/C system, keep the workspace well ventilated.


           Keep the A/C refrigerant away from flame.

           Collect and dispose the refrigerant as required.


                                                      1 .    Collect the Refrigerant
                                                      (a)    Connect the connectors of the A/C refrigerate
                                                             collecting/filling system to the high and low
                                                             ends of the A/C system respectively.










                                           ftwx611012


                                                      (b)    Turn on the high pressure and low pressure
                                                             valves of the A/C refrigerate collecting/filling
                                                             system.
                                                      (c)    Select the "Refrigerant Collecting" option of
                                                             the A/C refrigerate collecting/filling system.
                                                             Start the system and the collecting operation.
                                                      (d)    Check the low pressure reading of the A/C
                                                             refrigerate collecting/filling system and turn
                                                             off the system when the collection is
                                                             complete.
                                           ftwx611013
                                                      (e)    Disconnect the connectors of the A/C
                                                             refrigerate collecting/filling system to the high
                                                             and low ends of the A/C system respectively.

                                                      2 .    Vacuum
                                                      (a)    Connect the connectors of the A/C refrigerate
                                                             collecting/filling system to the high and low
                                                             ends of the A/C system respectively.










                                           ftwx611012