HEATER AND AIR CONDITIONING - REFRIGERANT                         61-15


                       Symptom              Possible Cause            Diagnostics                Action
                                                                                            expansion valve
                                                                                            with compressed
                                                                                            air.                     61
                                            blocked by steam                              • Replace the
                                            or dirt.                                        condenser.
                  condensing/drying       • The flow of the                               • Vacuum the system
                  can or expansion          refrigerant is                                  and Add some
                  valve.                    intervened by                                   refrigerant.
                                            leakage in the                                • If any leakage in
                                            expansion valve.                                the expansion
                                                                                            valve, replace it.
                                                                                          • Check for leaking
                                                                                            points.


                 •      Unsmooth circulation of refrigerant (condition: ineffective cooling system)



























                       Symptom              Possible Cause            Diagnostics                Action

                  Low pressure at both                                                    • Replaced the
                  high and low ends.      Refrigerant blocked                               damaged parts
                                                                  System blocked
                  Frost on the            by dirt                                         • Replace the
                  condenser pipe.                                                           condenser


                 •      Refrigerant not circulating (condition: cooling system works intermittently)