Page 2023 - Workshop Manual - Tunland (2017)
P. 2023

HEATER AND AIR CONDITIONING - REFRIGERANT                         61-17


                       Symptom              Possible Cause            Diagnostics                Action
                                                                                          • Clean the
                                                                                            condenser.
                                                                                          • Check the                61
                                          • Overly refrigerant    • Refrigerant overly      operation of the
                                            leads to insufficient   filled.                 condenser fan.
                  High pressure at both
                                            cooling.              • Dirty condenser.      • Replace the
                  low and high ends.
                                          • Poor radiation at     • Defect in condenser     condenser.
                                            the condenser.          fan.                  • Check whehter the
                                                                                            refrigerant volume
                                                                                            in the system meets
                                                                                            the standard.


                 •      Air in the cooling system (condition: cooling system not working)



























                       Symptom              Possible Cause            Diagnostics                Action

                                                                                          • Check whether the
                  High pressure at both                                                     coolant is dirty or
                                                                  • Air in the cooling
                  low and high ends.      Air in the cooling                                inadequate.
                                                                    system.
                  Low pressure pipe is    system.                                         • Vacuum the system
                                                                  • Insufficient vacuum.
                  hot.                                                                      and refill the
                                                                                            refrigerant.


                 •      Defective expansion valve (condition: ineffective cooling)