61-14                   HEATER AND AIR CONDITIONING - REFRIGERANT








      61


















                  Symptom              Possible Cause            Diagnostics                Action
                                    Steam in the cooling    • Fluid reservior is
                                    system is condensed                             • Replace the
                                                              overly saturated.
            During operation, the in the expansion                                    condenser.
                                                            • Steam is
            pressure at the low     valve hole and the                              • Discharge the
                                                              condensed in the
            end is sometimes        return pipe stops                                 steam inside the
                                                              expansion valve
            vacuum, and is          working from time to      hole and blocks the     return pipe.
            normal in other times time. When it is                                  • Add some
                                                              flow of the
                                    melted, it returns to                             refrigerant.
                                                              refrigerant.
                                    normal.

           •      Insufficient cooling (condition: ineffective cooling system)



























                  Symptom              Possible Cause            Diagnostics                Action

            Vaccum at the low       • System leakage -      System leakage -        • Check the
            end and low pressure      check connector
                                                            insufficient              expansion valve.
            at the high end. Frost    and exposed parts.
            or dew on the pipes     • The flow of the       refrigerant, unable to • Blow off the dirt
            before and after the      refrigerant is        circulate.                inside the