Page 2024 - Workshop Manual - Tunland (2017)
P. 2024

61-18                   HEATER AND AIR CONDITIONING - REFRIGERANT








      61


















                  Symptom              Possible Cause            Diagnostics                Action
                                                                                    • Check and replace
                                                            • Overly refrigerant in   the expansion
            High pressure at both
                                                              the low pressure        valve.
            high and low ends.      Defective expansion       pipe                  • Ensure the
            Frost or dew at the     valve
                                                            • Dirty or blocked        refrigerant volume
            low end.
                                                              expansion valve.        in the system meets
                                                                                      the standard.


           •      Defective compressor (condition: no cooling)



























                  Symptom              Possible Cause            Diagnostics                Action
                                                            • Defective             • Repair or replace
            Overly high at the low                            compressor.
                                      Internal leakage in                               the compressor.
            end and overly low at                           • Leakage in the
                                         compressor                                 •     Eliminate the
                the high end.                                 damaged valve or          system leakage.
                                                              moving part.


           2 .    Check for leakage with soap solution