Page 2019 - Workshop Manual - Tunland (2017)
P. 2019

HEATER AND AIR CONDITIONING - REFRIGERANT                         61-13

                 REFRIGERANT

                 CHECK

                 Leakage test can only be performed when the pressure inside the A/C system is no less than
                                                                                                                     61
                 0.196MPa. However, don't inject compressed air into the system, or the moisture, dust or
                 other impurities in the air may deteriorate the drying agent or contaminate the system. Check
                 refrigerant leakage in any of the following methods:
                 1 .    Measure the system pressure with manifold pressure gauge
                 (a)    It detects the defect with a manifold pressure gauge. Read the manifold pressure
                        gauge under the following conditions.
                        Test conditions:

                        Inlet temperature: 30 ~ 35℃
                        Engine RPM: 1500
                        Blower RPM: Max.

                        Temperature switch: Cool
                        A/C switch: On

                        All doors open
                      CAUTION

                 The tables below show the data when the cooling system is switched on, without
                 vacuuming before refrigerant replacement.


                                                           •      Pressure gauge reading in normal
                                                                  operation:
                                                                  Low pressure: 0.2–0.4MPa

                                                                  High pressure: 1.2–2.0MPa













                 •      Steam in the system (condition: no cooling intermittently)