Page 374 - Workshop Manual - Tunland (2017)
P. 374
04-236 DIAGNOSTICS - POWER DOOR LOCK CONTROL SYSTEM
(a) Disconnect connector J008 of power window
switch, left front door.
04
(b) Use multimeter to measure the resistance
between stitch 11 of connector J008 of power
window switch of left front door and the
ground.
Standard electrical resistance (check whether
there existent an open circuit)
Multimeter
Standard value
connection
J008(1)-ground < 2 Ω
Check whether the result is normal?
Yes> go to step 4
No > Maintenance or replace harness.
4 . Check circuit of body controller
(a) Disconnect connector C035, body controller.