04-236               DIAGNOSTICS - POWER DOOR LOCK CONTROL SYSTEM

                                                      (a)    Disconnect connector J008 of power window
                                                             switch, left front door.







      04














                                                      (b)    Use multimeter to measure the resistance
                                                             between stitch 11 of connector J008 of power
                                                             window switch of left front door and the
                                                             ground.
                                                      Standard electrical resistance (check whether
                                                      there existent an open circuit)

                                                             Multimeter
                                                                                      Standard value
                                                             connection

                                                           J008(1)-ground                 < 2 Ω







           Check whether the result is normal?
           Yes> go to step 4

           No > Maintenance or replace harness.

           4 .    Check circuit of body controller

                                                      (a)    Disconnect connector C035, body controller.