DIAGNOSTICS - POWER DOOR LOCK CONTROL SYSTEM                       04-241

                 Yes> go to step 9

                 No> replace body controller

                 9 .    Check harness and connector (body controller-power window switch, left front
                        door )

                                                           (a)    Disconnect connector J007, lock assy, left         04
                                                                  front door.























                                                           (b)    Disconnect body controller C036 connector.



















                                                           (c)    Use multimeter to measure the resistance
                                                                  between stitches 19 and 10 of connector
                                                                  J007of lock assy for the left front door and
                                                                  stitches E27, E28 of connector C036 of body
                                                                  controller.
                                                                  Standard resistance (check whether there
                                                                  is short circuit)

                                                                 Multimeter
                                                                                      Standard value
                                                                 connection

                                                             J007(9)-C036(E28)
                                                                                           < 2 Ω
                                                            J007(10)-C036(E27)




                 Check whether the result is normal?