Page 381 - Workshop Manual - Tunland (2017)
P. 381
DIAGNOSTICS - POWER DOOR LOCK CONTROL SYSTEM 04-243
(a) Disconnect connector G006 of door lock
motor of right front door.
(b) Disconnect connector I005of door lock motor
of left rear door.
(c) Disconnect connector H005 of door lock motor
of right rear door.
04
(e) Use multimeter to measure the resistance
between stitches B1, B3 of connector C033
of body controller and stitches 4 and 1.
Standard resistance (check whether there
is short circuit)
Multimeter
Standard value
connection
C033(B1)-G006(4)or
H005(4)orI005(4)
≤ 2 Ω
C033(B3)-G006(1)or
H005(1)orI005(1)
Check whether the result is normal?
Yes> go to step 12
No > Maintenance or replace harness.
12 . Check signal output circuit, body controller