Page 386 - Workshop Manual - Tunland (2017)
P. 386

04-248               DIAGNOSTICS - POWER DOOR LOCK CONTROL SYSTEM

                                                      (a)    Use master control switch to unlock the door,
                                                             meanwhile use multimeter to measure the
                                                             voltage between stitch 4 of connector G006
                                                             of the right front lock motor and the ground.

                                                             Standard voltage

      04                                               Multimeter connection          Standard value
                                                                                      Battery voltage

                                                           G006(4)-ground         (Lasts about 0.3 ~ 1.1
                                                                                             s)








           Check whether the result is normal?
           Yes> replace lock motor, right front door
           No> Repair the open circuit between stitch 4 of connector G006 of the lock motor,
           right front door and stitch B3 of connector C033 of the body controller.
   381   382   383   384   385   386   387   388   389   390   391