04-240               DIAGNOSTICS - POWER DOOR LOCK CONTROL SYSTEM

                                                      (b)    Use multimeter to measure the resistance
                                                             between stitch 7 of connector J007 of lock
                                                             assy of left front door and the ground.
                                                             Standard electrical resistance (check
                                                             whether there existent an open circuit)

      04                                                   Multimeter
                                                                                Standard value
                                                           connection
                                                         J007(7)-ground              < 2 Ω










           Check whether the result is normal?
           Yes> go to step 8
           No > Maintenance or replace harness.


           8 .    Check circuit of body controller

                                                      (a)    Disconnect body controller C036 connector.



















                                                      (b)    Use multimeter to measure the resistance
                                                             between. stitches E27, E28 of connector C036
                                                             of the body controller and the ground.
                                                             Standard resistance (check whether there
                                                             is short circuit)

                                                           Multimeter
                                                                                Standard value
                                                           connection

                                                        C036(E27)-ground
                                                                                     < 2 Ω
                                                        C036(E28)-ground






           Check whether the result is normal?
   373   374   375   376   377   378   379   380   381   382   383