Page 411 - Workshop Manual - Tunland (2017)
P. 411

DIAGNOSTICS - WIPER & WASHER                             04-273

                                                           (c)    Measure the electrical resistance based on
                                                                  the value in the following form.
                                                                  Standard resistance (check whether there
                                                                  is an open circuit)


                                               C012         Multimeter connection          Standard value
                                                                                                                     04
                                                               C012 (3) - ground                < 2 Ω









                                                 ftwxd041371


                 Check whether the result is normal?
                 Yes> go to step 6
                 No > Maintenance or replace harness.


                 6 .    Check the harness and connectors (combination switch - BCM control unit)
                 (a)    Ignition Switch: OFF.

                                                           (b)    Disconnect the connector C012 of
                                                                  combination switch (wiper).














                                                 ftwx641020

                                                           (c)    Disconnect connector C035 of BCM control
                                                                  unit.














                                                 ftwxd041025
   406   407   408   409   410   411   412   413   414   415   416