Page 437 - Workshop Manual - Tunland (2017)
P. 437

DIAGNOSTICS - AIR CONDITIONING SYSTEM                        04-299

                                                           (c)    Measure the electrical resistance based on
                                                                  the value in the following form.
                                                                  Standard electrical resistance (check
                                                                  whether there existent an open circuit)

                                                            Multimeter connection          Standard value
                                                                                                                     04
                                                               F33(5A)—C021                     < 2 Ω
                                                                     (A1)











                 Check whether the result is normal?
                 Yes> go to step 4.
                 No > Maintenance or replace harness.


                 4 .    Check the harness and connectors (air conditioner controller - ground)
                 (a)    Disconnect battery negative cable.

                                                           (b)    Disconnect connector C021 of air-conditioner
                                                                  controller.
   432   433   434   435   436   437   438   439   440   441   442