DIAGNOSTICS - AIR CONDITIONING SYSTEM                        04-303


                 (a)    Disconnect battery negative cable.
                 (b)    Unplug the blower relay R03.

                                                           (c)    Check the blower relay R03.

                                                                  Standard resistance:
                                                                                                                     04
                                                                                Multimeter
                                                                                                   Specified
                                                              Conditions        connection
                                                                                                     value
                                                                                   stitch
                                                                Normal
                                                                situation         85–86            Breakover

                                                              Apply power
                                                             supply voltage
                                                               to position        30–87              <2Ω
                                                             between stitch
                                                               85 and 86,



                 Check whether the result is normal?
                 Yes> go to step 4

                 No > Replace the blower relay, and verify again whether the failure exists.

                 4 .    Check the harness and connectors (blower relay – blower motor)
                 (a)    Disconnect battery negative cable.

                                                           (b)    Disconnect the connector C025 of blower.
                                                           (c)    Unplug the blower relay R03.