Page 444 - Workshop Manual - Tunland (2017)
P. 444

04-306                     DIAGNOSTICS - AIR CONDITIONING SYSTEM

           Check whether the result is normal?

           Yes> go to step 7.
           No > Maintenance or replace harness.

           8 .    Check the harness and connectors (blower speed control resistor - ground)

      04     (a)  Disconnect battery negative cable.

                                                      (b)    Disconnect the connector C024 of blower
                                                             speed control resistor.























                                                      (d)    Measure the electrical resistance based on
                                                             the value in the following form.
                                                             Standard electrical resistance (check
                                                             whether there existent an open circuit)

                                                       Multimeter connection          Standard value

                                                         C024(1)- ground                   <2Ω













           Check whether the result is normal?
           Yes > Go to step 8.
           No > Maintenance or replace harness.


           8 .    Check harness and connector (blower speed control resistor - air conditioning
                  controller).
           (a)    Disconnect battery negative cable.
   439   440   441   442   443   444   445   446   447   448   449