Page 440 - Workshop Manual - Tunland (2017)
P. 440

04-302                     DIAGNOSTICS - AIR CONDITIONING SYSTEM

           Diagnostic steps

           1 .    Check fuse

           (a)    Disconnect battery negative cable.

                                                      (b)    Check the fuse inside the fuse box of engine
      04                                                     compartment:
                                                             •     F28(125A)
                                                             •     F11(60A)

                                                      (c)    Check the fuse inside the vehicle-body fuse
                                                             box:

                                                             •     F17(5A)
                                                             •     F33(5A)
                                                             •     F44(30A)







           Check whether the result is normal?

           Yes> go to step 2
           No> replace fuse


           2 .    Check the starter relay
           (a)    Disconnect battery negative cable.
           (b)    Unplug the relay R4 of starter.

                                                      (c)    Check the relay R4 of no-load starter.
                                                             Standard resistance:

                                                                           Multimeter
                                                                                             Specified
                                                        Conditions        connection            value
                                                                             stitch
                                                           Normal
                                                          situation            1-2           Breakover

                                                        Apply power
                                                       supply voltage
                                                         to position           3-4              <2Ω
                                                       between stitch
                                                          1 and 2,


           Check whether the result is normal?

           Yes> go to step 3
           No > Replace the starter relay, and verify again whether the failure exists.


           3 .    Check the blower relay