Page 438 - Workshop Manual - Tunland (2017)
P. 438

04-300                     DIAGNOSTICS - AIR CONDITIONING SYSTEM

                                                      (c)    Measure the electrical resistance based on
                                                             the value in the following form.
                                                             Standard electrical resistance (check
                                                             whether there existent an open circuit)

                                                       Multimeter connection          Standard value
      04
                                                        C021(B1)- ground

                                                       C021(B19)- ground                  < 2 Ω
                                                       C021(B20)- ground








           Check whether the result is normal?
           Yes > Replace the air conditioner controller, and verify again whether the failure exists.
           No > Maintenance or replace harness.
   433   434   435   436   437   438   439   440   441   442   443